Fouling Resistant membranes

Membranes intended for applications with feed water that has fouling potential, subject to appropriate pretreatment.

Membrane system for challenging feed water

Quick Summary

The Fouling Resistant series is intended for challenging feed water where membrane fouling is a concern. Suitability depends on pretreatment, water quality and operating conditions, and is reviewed by the Nimbus team before any model is recommended.

Suitable application

Reviewed for water sources with significant organic, colloidal or biological loading.

Selection conditions

Fit is determined by feed water characterization, the pretreatment train and planned cleaning frequency.

Fouling Resistant Series Models

This series is intended for applications where feed water conditions may increase fouling potential. Final model selection depends on water quality and operating conditions.

NIM-BW-8040XLFR

Most Popular in Israel

Fouling Resistant Membrane

8040 Format

Nominal permeate flow
11,500 GPD (43.5 m³/d)
Nominal salt rejection
99.75%
Active Membrane Area
400 ft² (37.2 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
400 ft² (37.2 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
7.9 in (201 mm)
Central Tube Diameter
1.125 in (28.6 mm)

Standard Test Conditions

Test Pressure
225 psi
Salt Concentration
2000 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-BW-FR-8040-LD

Fouling Resistant Membrane

8040 Format

Nominal permeate flow
10,500 GPD (39.7 m³/d)
Nominal salt rejection
99.75%
Active Membrane Area
400 ft² (37.2 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
400 ft² (37.2 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
7.9 in (201 mm)
Central Tube Diameter
1.125 in (28.6 mm)

Standard Test Conditions

Test Pressure
225 psi
Salt Concentration
2000 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-BW-FR-4040

Fouling Resistant Membrane

4040 Format

Nominal permeate flow
2,300 GPD (8.7 m³/d)
Nominal salt rejection
99.6%
Active Membrane Area
85–90 ft² (7.9–8.4 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
85–90 ft² (7.9–8.4 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
3.9 in (99 mm)
Central Tube Diameter
0.75 in (19.0 mm)

Standard Test Conditions

Test Pressure
225 psi
Salt Concentration
2000 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

Membranes For Challenging Feed Conditions

This category may be reviewed where operating conditions create additional treatment and maintenance considerations.

Selecting a water-treatment solution is an engineering and operational process. It begins with the water source, composition, variation over time, required flow, target quality, operating hours, site constraints and maintenance approach. A technology name alone is not sufficient to establish suitability.

Website information is general and is not a quotation, binding specification, fit approval or engineering approval. Scope, equipment, performance and conditions will be determined only after data review and an approved Nimbus proposal.