High Flow membranes

Membranes intended for applications requiring relatively high permeate flow, subject to feed conditions and approval.

High-capacity industrial membrane array

Quick Summary

The High Flow series is intended for applications where system output is a key consideration. Suitability depends on feed water quality, system design and operating conditions, and is reviewed by the Nimbus team before any model is recommended.

Suitable application

Reviewed for systems with a significant throughput requirement relative to installed area.

Selection conditions

Fit is determined by feed flow, water quality and system configuration.

High Flow Models

The models shown include all Nimbus specifications carrying the HF designation in the approved catalog.

NIM-XLE-8040-HF

High Flow Membrane

8040 Format

Nominal permeate flow
13,000 GPD (49.2 m³/d)
Nominal salt rejection
99%
Active Membrane Area
440 ft² (40.9 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
440 ft² (40.9 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
7.9 in (201 mm)
Central Tube Diameter
1.125 in (28.6 mm)

Standard Test Conditions

Test Pressure
100 psi
Salt Concentration
500 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-XLE-4040-HF

High Flow Membrane

4040 Format

Nominal permeate flow
3,500 GPD (13.2 m³/d)
Nominal salt rejection
99%
Active Membrane Area
85–90 ft² (7.9–8.4 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
85–90 ft² (7.9–8.4 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
3.9 in (99 mm)
Central Tube Diameter
0.75 in (19.0 mm)

Standard Test Conditions

Test Pressure
100 psi
Salt Concentration
500 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-BW-LE-8040-HF

High Flow Membrane

8040 Format

Nominal permeate flow
12,500 GPD (47.3 m³/d)
Nominal salt rejection
99.5%
Active Membrane Area
440 ft² (40.9 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
440 ft² (40.9 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
7.9 in (201 mm)
Central Tube Diameter
1.125 in (28.6 mm)

Standard Test Conditions

Test Pressure
150 psi
Salt Concentration
1500 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-BW-LE-4040-HF

High Flow Membrane

4040 Format

Nominal permeate flow
2,700 GPD (10.2 m³/d)
Nominal salt rejection
99.5%
Active Membrane Area
85–90 ft² (7.9–8.4 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
85–90 ft² (7.9–8.4 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
3.9 in (99 mm)
Central Tube Diameter
0.75 in (19.0 mm)

Standard Test Conditions

Test Pressure
150 psi
Salt Concentration
1500 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-BW-8040-HF

High Flow Membrane

8040 Format

Nominal permeate flow
13,000 GPD (49.2 m³/d)
Nominal salt rejection
99.55%
Active Membrane Area
440 ft² (40.9 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
440 ft² (40.9 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
7.9 in (201 mm)
Central Tube Diameter
1.125 in (28.6 mm)

Standard Test Conditions

Test Pressure
225 psi
Salt Concentration
2000 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-BW-4040-HF

High Flow Membrane

4040 Format

Nominal permeate flow
2,900 GPD (11 m³/d)
Nominal salt rejection
99.5%
Active Membrane Area
85–90 ft² (7.9–8.4 m²)
Max Operating Pressure
600 psi (41 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
85–90 ft² (7.9–8.4 m²)

Operating Limits

Max Operating Pressure
600 psi (41 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
3.9 in (99 mm)
Central Tube Diameter
0.75 in (19.0 mm)

Standard Test Conditions

Test Pressure
225 psi
Salt Concentration
2000 ppm NaCl
Test Temperature
25°C
Recovery
15%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-SW-8040-HF

Most Popular in Israel

High Flow Membrane

8040 Format

Nominal permeate flow
9,000 GPD (34.1 m³/d)
Nominal salt rejection
99.85%
Active Membrane Area
440 ft² (40.9 m²)
Max Operating Pressure
1,200 psi (83 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
440 ft² (40.9 m²)

Operating Limits

Max Operating Pressure
1,200 psi (83 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
7.9 in (201 mm)
Central Tube Diameter
1.125 in (28.6 mm)

Standard Test Conditions

Test Pressure
800 psi
Salt Concentration
32000 ppm NaCl
Test Temperature
25°C
Recovery
8%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

NIM-SW-4040-HF

High Flow Membrane

4040 Format

Nominal permeate flow
2,000 GPD (7.6 m³/d)
Nominal salt rejection
99.8%
Active Membrane Area
85–90 ft² (7.9–8.4 m²)
Max Operating Pressure
1,200 psi (83 bar)

Nominal flow and rejection at the model’s test conditions; not a commitment to field performance.

Active Membrane Area

Active Membrane Area
85–90 ft² (7.9–8.4 m²)

Operating Limits

Max Operating Pressure
1,200 psi (83 bar)
Max Operating Temperature
45°C (113°F)
Continuous Operating pH
2.0–11.0
CIP pH Range
1.0–12.0
Maximum Feed Water Silt Density Index
SDI15 < 5.0
Free Chlorine Tolerance
< 0.1 ppm
Max Pressure Drop per Element
15 psi (1.0 bar)

Dimensions

Length
40.0 in (1,016 mm)
Outer Diameter
3.9 in (99 mm)
Central Tube Diameter
0.75 in (19.0 mm)

Standard Test Conditions

Test Pressure
800 psi
Salt Concentration
32000 ppm NaCl
Test Temperature
25°C
Recovery
8%
Test pH
7.5-8.0

Values are measured at the stated test conditions and are not a commitment to field performance. Engineering review is required for every application.

Request a Quote

Selecting a water-treatment solution is an engineering and operational process. It begins with the water source, composition, variation over time, required flow, target quality, operating hours, site constraints and maintenance approach. A technology name alone is not sufficient to establish suitability.

Website information is general and is not a quotation, binding specification, fit approval or engineering approval. Scope, equipment, performance and conditions will be determined only after data review and an approved Nimbus proposal.